TZ JOIST ANGLE 1-1/2X1-1/4IN - Case of 100
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505, L.A. City RR25303, DSA PA-076 and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 ga.
Tz Mudsill Anchor 10in 18ga - Case of 50
For securing mudsills and framing into concrete slabs or poured stem walls. Not for block installation or securing concrete sections together between cold joints. Features prevent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12 in of the end of each section. Meets NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
FRAME ANGLE MULTI-PURPOSE STL - Case of 100
Use for joist to header, rafter to plate, stud to plate or 1 in foam board installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
TZ FRAME ANGLE MULTI-PURPOSE - Case of 100
Use for joist to header, rafter to plate, stud to plate or 1 in foam board installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
TZ WET ANCH 3-1/2X3-1/4X4-3/4 - Case of 12
Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires two 1/2 in HDG bolts or 12 HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337 and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
STRINGER HGR 1-7/16X1-7/16X5IN - Case of 50
The CSH-TZ concealed stringer hanger provides a method of connecting a stair stringer with a hidden hanger. The seat of the hanger is adjustable to match the slope of the stair stringer. The reversible design allows the connector to be used on the left, right or interior stringers. The CSH-TZ may be used with USP's SCA stair angles for a complete, easy-to-use stair framing solution. .
TZ ANGE CL 1-7/16X1-7/16X2-3/4 - Case of 100
Eliminates toenailing and increases strength. Requires 10d x 1-1/2 in nails for installation. 1-7/16 in W1 x 1-7/16 in W2 x 2-3/4 in L, 18 ga. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes.
TZ ANGLE CL 1-5/16X2-3/8X4-7/8 - Case of 100
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple zinc clips require 10d HDG or 16d HDG nails. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes.
TZ ANGLE 1-5/16X2-3/8X6-15/16 - Case of 100
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple zinc clips require 10d HDG or 16d HDG nails. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes.