Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES
SEARCH SUBCATEGORIES BELOW TO FIND MORE ITEMS:
BREAKER BOXES MOBILE HOME LOAD CENTERS SPA PANEL BOXES
GENERATOR PANEL BOXES SAFETY SWITCHES DISCONNECT BOXES
METER BASES PANEL BOX ACCESSORIES
Sort By:
1 2 3 ... 5
Cutler Hammer BRFPP Filler Plate GROUND BAR 7 HOLE CONSUMER PK GE THFILLER Rectangle Filler Plate
Plastic (snap-in) for type BR 1 in space. May also be used with 400 and 600 A load centers. For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 to 8 AWG copper or 12 to 8 AWG aluminum terminals and 3 large holes for 14 to 4 AWG copper or 12 to 4 AWG aluminum terminals. UL listed and ANSI certified. 6-7/8 in H x 2-7/8 in W x 1/2 in depth, 0.105 lb. GE Filler Plate Kit, 6-7/8 in Length, 2-7/8 in Width, 3/4 in Height
LUG KIT NO6-2/0 NEUTRAL/GROUND Square D QOFPCP Filler Plate Square D PK4GTACP Ground Bar Kits
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL listed. 2-7/8 in H x 3/4 in W x 6-7/8 in D, 0.07 lb. Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
Square D QO70AN Auxiliary Neutral Lug Kit Square D HOMFPCP Filler Plate Siemens EC38595 Closure Plate
Made for QO load centers. Field installed for number 12 to 2 Al or number 14 to 4 Cu wire. QO accessories can only be used with QO load centers. Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified. Siemens Closure Plate, 3/4 in Nominal, Dimensions: 12.8 X 5.2 X 3.7 in
Square D HOM100AN Neutral Lug Kit GROUND BAR 24 HOLE PM-GOLD PK Square D ACPCP Closing Plate
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 to 1/0 copper and aluminum wire. UL listed and ANSI certified. Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL listed and ANSI certified. 11 in H x 3-1/2 in W x 1/2 in D, 0.304 lb. Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA listed.
Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch GE Electrical TFN60RCP AC Disconnect Switches Cutler-Hammer DPF221RP AC Disconnect Switches
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed. An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
Square D QO200TRCP Molded Non-Fusible Disconnect Switch Siemens ECLK2125 Sub-Feed Lug Kit Square D QO2L30SC Load Center
Air conditioning disconnects from Schneider Electric are Underwriters Laboratories? (UL?) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code? (NEC?) requirements for a disconnecting means on residential and commercial air conditioning installations, as well as other single-phase applications, such as swimming pools and pump houses. Sub feed lug kit. 125 A. 2-pole. Lugs to sub feed to another panel. Main lug load center, indoor, 30 A, 2 space/2 circuits. Accommodates both overhead and underground feed applications. 1 in maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL listed.
Eaton BR24L70SP Load Center Square D S106 Replacement Screw Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws. Single phase, 2 pole, 2 wire, 240 VAC. Rated 3 hp at 120 V, 10 hp at 240 V. For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No GB4 ground bar and No 360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5 in x 8-5/8 in x 3-1/2 in. UL listed file No E5239.
Homeline Square D HOM24L70S Load Center Cutler-Hammer DPF222RP AC Disconnect Switches Homeline Square D HOM24L70F Load Center
Main lug indoor load center, 70 A, 2 space/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 V. NEMA type 1 enclosure. Expandable load center capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian Homeline breakers. An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Main lug indoor load center, 70 A, 2 space/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4 in knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL listed.
Eaton BR24L70FP Load Center Siemens Energy WN2060U AC Disconnect Switches Cutler Hammer BRL200 Main Lug Kit
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Single phase, 2 pole, 2 wire, 240 V, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32 in x 7-5/16 in x 2-7/32 in. UL listed. Cutler-Hammer Main Lug Kit, 120/240 VAC, 200 A, 1 to 300 kcmil Wire
Eaton CH2L70SP Load Center GE Electrical TPN60R1 AC Disconnect Switches Eaton BR48L125FP Load Center
Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion-resistant GE Noryl thermoplastic resin. 2-pole, 3-wire, 120/240 VAC, rated 10 hp. 5-3/4 in x 8 in x 3-1/8 in. UL1429 enclosed pullout switch, UL Listed. Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kAIC, Cable Size: 14 to 1/0 AWG, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Flush Mounting
   
 
1 2 3 ... 5